16
MN (Menu Selection; GET/SET; K3 and KX3 variants)
SET/RSP format: MNnnn; where nnn is shown in Table 5 (K3) or Table 6 (KX3). MN255 is returned if the
menu is not in use. MN commands can be sent in any order. To exit the menu, send MN255. To change the
parameter, use UP / DN (or MP and MQ commands—see table notes). IMPORTANT: TECH MD menu entry
must be set to ON to access tech-mode menu entries; otherwise MN will skip these entries. Use MN072 to access
the TECH MD menu entry. On the KX3, tech-mode parameters are locked by default when accessed at the
radio, but are automatically unlocked when accessed via the MN/MP/MQ commands.
Table 5 K3 MN values. ‡ = can be read/set using MP command. nnn is permanently associated with a menu
entry, even if entries are moved. md is the data mode pertaining to a menu entry: CW, SB (LSB/USB), DT
(DATA), AM, or FM. pwr is LP (QRP), HP (QRO), or MW (0 to 2 mW, using the KXV3 transverter I/O jacks).